Description:
Heating Refrigeration temperature control system is mainly applied to the glass reactor, metal reactor, bioreactor heating and cooling, temperature control, especially for needy during the reaction heating, exothermic process control.
FEATURES :
1. The system with air -cooled machine
2. Temperature control of digital temperature adjustment and indication
3. The system for precisely controlling the temperature of applications and processes of reactor.
4. The system is a closed liquid circulation system with the expansion vessel
5. Wide temperature ranges without fluid change
6.Multi-alarming devices (over-temperature alarm, sensor alarm, high pressure alarm, overheat alarm compressor)
Model | SUNDI-510W SUNDI-510 | SUNDI-520W SUNDI-520 | SUNDI-525W SUNDI-525 | SUNDI-530W | |
Oil temperature range | -55°C~250°C | -55°C~250°C | -55°C~250°C | -55°C~250°C | |
controller | PID | ||||
Communication | RS485 | ||||
Temperature control | Option:process temperature control or jacket oil temperature control | ||||
Temperature difference | Set or control the temperature difference between jacket oil and raw material process | ||||
Temperature feedback | Jacket oil :PT100 Raw material process:PT100 | ||||
Temperature accuracy | ±1°C | ±1°C | ±1°C | ±1°C | |
Heating power | 5500W | 7500W | 10000W | 20000W | |
Cooling power | 250°C | 5500W | 7500W | 10000W | 20000W |
100°C | 5000W | 7000W | 10000W | 20000W | |
20°C | 5000W | 7000W | 10000W | 20000W | |
0°C | 5000W | 7000W | 10000W | 20000W | |
-20°C | 2850W | 4200W | 6000W | 11000W | |
-40°C | 900W | 1500W | 2000W | 3750W | |
Circulation pump | Max35L/min 1.5BAR | Max50L/min 1.5BAR | Max50L/min 2.5BAR | Max110L/min 2BAR | |
Compressor | Tecumseh | Tecumseh | Tecumseh | Maneurop | |
Evaporator | KAORI Plate heat exchanger | KAORI Plate heat exchanger | KAORI Plate heat exchanger | KAORI Plate heat exchanger | |
Input and display | 7-inch colour touch screen,temperature graph display | ||||
Security protection | Self-diagnosis function;freezer overload protection;high pressure switch,overload relay,thermal protection device,liquid low level protection,high temperature protection and temperature fault protection | ||||
Closed circulation system | The whole system is closed circulation system,low temperature did not absorb water vapor, high temperature did not produce the oil miss.although at high temperature,pressure will not go up during the system is operating.at low temperature,the system will supplementary oil | ||||
Refrigerant | R404A | R404A | R404A | R404A | |
Connection size | DN20 | DN20 | DN-25 | DN-25 | |
Water cooled type Cooling water at 15 degree | 1200L/H 1.5bar~4bar | 1600L/H 1.5bar~4bar | 2000L/H 1.5bar~4bar | 4000L/H 1.5bar~4bar | |
Dimension (water cooled) (air cooled) |
600*700*1050 500*680*1450 |
600*700*1050 550*700*1450 |
600*700*1050 700*700*1650 |
750*800*1350
| |
weight (water cooled) (air cooled) |
135KG 155KG |
155KG 185KG |
190KG 220KG |
300KG | |
Power | AC400V50HZ 7800W(max) | AC400V50HZ 11000W(max) | AC400V50HZ 15500W(max) | AC400V50HZ 29000W(max) | |
Case material | SUS 304 | SUS 304 | SUS304 | SUS304 | |
Reactor capacity | 20L,30L,50L | 30L,50L,75L,100L | 50L,75L,100L,150L | 75L,100L,150L,200L |
refrigerated heating circulator - 55 to 250 degree